Vendor Siemens Ag
Product SINUMERIK 808D V4.7, SINUMERIK 808D V4.8, SINUMERIK 828D V4.7, SINUMERIK 840D sl V4.7, SINUMERIK 840D sl V4.8
Weakness CWE-693
Published December 12, 2018
Last update August 5, 2024

CVSS base score

What the vulnerability does

01Description

A vulnerability has been identified in SINUMERIK 808D V4.7 (All versions), SINUMERIK 808D V4.8 (All versions), SINUMERIK 828D V4.7 (All versions < V4.7 SP6 HF1), SINUMERIK 840D sl V4.7 (All versions < V4.7 SP6 HF5), SINUMERIK 840D sl V4.8 (All versions < V4.8 SP3). A local attacker with elevated user privileges (manufact) could modify a CRAMFS archive so that after reboot the system loads the modified CRAMFS file and attacker-controlled code is executed with root privileges. The security vulnerability could be exploited by an attacker with local access to the affected systems. Successful exploitation requires elevated user privileges (manufact) but no user interaction. The vulnerability could allow an attacker to compromise confidentiality, integrity and availability of the system. At the time of advisory publication no public exploitation of this security vulnerability was known.

Key dates

02Disclosure timeline

December 12, 2018 CVE published
August 5, 2024 Record updated