CVE-2019-13947 MEDIUM

CVE-2019-13947

Vendor Siemens
Product Control Center Server (CCS)
Weakness CWE-317
Published December 12, 2019
Last update August 5, 2024

CVSS base score

4.9/10
Attack vector Network
Attack complexity Low
Privileges required High
User interaction None
Confidentiality High
Integrity None

CVSS vector

CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N/E:F/RL:U/RC:C

What the vulnerability does

01Description

A vulnerability has been identified in Control Center Server (CCS) (All versions < V1.5.0). The user configuration menu in the web interface of the Control Center Server (CCS) transfers user passwords in clear to the client (browser). An attacker with administrative privileges for the web interface could be able to read (and not only reset) passwords of other CCS users.

Key dates

02Disclosure timeline

December 12, 2019 CVE published
August 5, 2024 Record updated

Related vulnerabilities

04Related CVE