CVE-2019-1890 HIGH

CVE-2019-1890: Cisco Nexus 9000 Series Fabric Switches ACI Mode Fabric Infrastructure VLAN Unauthorized Access Vulnerability

Vendor Cisco
Product Cisco NX-OS System Software in ACI Mode 11.0.1b
Weakness CWE-284
Published July 4, 2019
Last update November 21, 2024

CVSS base score

7.4/10
Attack vector Adjacent
Attack complexity Low
Privileges required None
User interaction None
Confidentiality None
Integrity High

CVSS vector

CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:C/C:N/I:H/A:N

What the vulnerability does

01Description

A vulnerability in the fabric infrastructure VLAN connection establishment of the Cisco Nexus 9000 Series Application Centric Infrastructure (ACI) Mode Switch Software could allow an unauthenticated, adjacent attacker to bypass security validations and connect an unauthorized server to the infrastructure VLAN. The vulnerability is due to insufficient security requirements during the Link Layer Discovery Protocol (LLDP) setup phase of the infrastructure VLAN. An attacker could exploit this vulnerability by sending a malicious LLDP packet on the adjacent subnet to the Cisco Nexus 9000 Series Switch in ACI mode. A successful exploit could allow the attacker to connect an unauthorized server to the infrastructure VLAN, which is highly privileged. With a connection to the infrastructure VLAN, the attacker can make unauthorized connections to Cisco Application Policy Infrastructure Controller (APIC) services or join other host endpoints.

Key dates

02Disclosure timeline

July 4, 2019 CVE published
November 21, 2024 Record updated