CVE-2021-22797 HIGH

CVE-2021-22797

Vendor Schneider Electric
Product EcoStruxure Control Expert
Weakness CWE-22 · Path traversal
Published March 28, 2022
Last update August 3, 2024

CVSS base score

7.8/10
Attack vector Local
Attack complexity Low
Privileges required None
User interaction Required
Confidentiality High
Integrity High

CVSS vector

CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H

What the vulnerability does

01Description

A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal) vulnerability exists that could cause malicious script to be deployed in an unauthorized location and may result in code execution on the engineering workstation when a malicious project file is loaded in the engineering software. Affected Product: EcoStruxure Control Expert (V15.0 SP1 and prior, including former Unity Pro), EcoStruxure Process Expert (2020 and prior, including former HDCS), SCADAPack RemoteConnect for x70 (All versions)

Key dates

02Disclosure timeline

March 28, 2022 CVE published
August 3, 2024 Record updated