CVE-2023-37459 MEDIUM

CVE-2023-37459: Out-of-bounds read when processing a received IPv6 packet

Vendor Contiki-Ng
Product contiki-ng
Weakness CWE-125
Published September 15, 2023
Last update September 25, 2024

CVSS base score

5.3/10
Attack vector Network
Attack complexity Low
Privileges required None
User interaction None
Confidentiality Low
Integrity None

CVSS vector

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N

What the vulnerability does

01Description

Contiki-NG is an operating system for internet-of-things devices. In versions 4.9 and prior, when a packet is received, the Contiki-NG network stack attempts to start the periodic TCP timer if it is a TCP packet with the SYN flag set. But the implementation does not first verify that a full TCP header has been received. Specifically, the implementation attempts to access the flags field from the TCP buffer in the following conditional expression in the `check_for_tcp_syn` function. For this reason, an attacker can inject a truncated TCP packet, which will lead to an out-of-bound read from the packet buffer. As of time of publication, a patched version is not available. As a workaround, one can apply the changes in Contiki-NG pull request #2510 to patch the system.

Key dates

02Disclosure timeline

September 15, 2023 CVE published
September 25, 2024 Record updated