CVE-2023-39464 HIGH

CVE-2023-39464: Triangle MicroWorks SCADA Data Gateway GTWWebMonitorService Unquoted Search Path Remote Code Execution Vulnerability

Vendor Triangle Microworks
Product SCADA Data Gateway
Weakness CWE-428
Published May 3, 2024
Last update August 2, 2024

CVSS base score

7.2/10
Attack vector Network
Attack complexity Low
Privileges required High
User interaction None
Confidentiality High
Integrity High

CVSS vector

CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H

What the vulnerability does

01Description

Triangle MicroWorks SCADA Data Gateway GTWWebMonitorService Unquoted Search Path Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute code on affected installations of Triangle MicroWorks SCADA Data Gateway. Although authentication is required to exploit this vulnerability, the existing authentication mechanism can be bypassed. The specific flaw exists within the configuration of the GTWWebMonitorService service. The path to the service executable contains spaces not surrounded by quotations. An attacker can leverage this vulnerability to execute arbitrary code in the context of root. Was ZDI-CAN-20538.

Key dates

02Disclosure timeline

May 3, 2024 CVE published
August 2, 2024 Record updated