CVE-2023-46283 HIGH

CVE-2023-46283

Vendor Siemens
Product Opcenter Execution Foundation
Weakness CWE-120
Published December 12, 2023
Last update January 14, 2025

CVSS base score

7.5/10
Attack vector Network
Attack complexity Low
Privileges required None
User interaction None
Confidentiality None
Integrity None

CVSS vector

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C

What the vulnerability does

01Description

A vulnerability has been identified in Opcenter Execution Foundation (All versions < V2407), Opcenter Quality (All versions < V2312), SIMATIC PCS neo (All versions < V4.1), SINEC NMS (All versions < V2.0 SP1), Totally Integrated Automation Portal (TIA Portal) V14 (All versions), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions < V17 Update 8), Totally Integrated Automation Portal (TIA Portal) V18 (All versions < V18 Update 3). The affected application contains an out of bounds write past the end of an allocated buffer when handling specific requests on port 4002/tcp. This could allow an attacker to crash the application. The corresponding service is auto-restarted after the crash.

Key dates

02Disclosure timeline

December 12, 2023 CVE published
January 14, 2025 Record updated