CVE-2023-46285 HIGH

CVE-2023-46285

Vendor Siemens
Product Opcenter Execution Foundation
Weakness CWE-20 · Input validation
Published December 12, 2023
Last update May 24, 2025

CVSS base score

7.5/10
Attack vector Network
Attack complexity Low
Privileges required None
User interaction None
Confidentiality None
Integrity None

CVSS vector

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C

What the vulnerability does

01Description

A vulnerability has been identified in Opcenter Execution Foundation (All versions < V2407), Opcenter Quality (All versions < V2312), SIMATIC PCS neo (All versions < V4.1), SINEC NMS (All versions < V2.0 SP1), Totally Integrated Automation Portal (TIA Portal) V14 (All versions), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions < V17 Update 8), Totally Integrated Automation Portal (TIA Portal) V18 (All versions < V18 Update 3). The affected application contains an improper input validation vulnerability that could allow an attacker to bring the service into a Denial-of-Service state by sending a specifically crafted message to 4004/tcp. The corresponding service is auto-restarted after the crash is detected by a watchdog.

Key dates

02Disclosure timeline

December 12, 2023 CVE published
May 24, 2025 Record updated