CVE-2023-5986 HIGH

CVE-2023-5986

Vendor Schneider Electric
Product EcoStruxure Power Monitoring Expert (PME)
Weakness CWE-601 · Open redirect
Published November 15, 2023
Last update December 2, 2024

CVSS base score

8.2/10
Attack vector Network
Attack complexity Low
Privileges required None
User interaction Required
Confidentiality High
Integrity Low

CVSS vector

CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:H/I:L/A:N

What the vulnerability does

01Description

A CWE-601 URL Redirection to Untrusted Site vulnerability exists that could cause an openredirect vulnerability leading to a cross site scripting attack. By providing a URL-encoded input attackers can cause the software’s web application to redirect to the chosen domain after a successful login is performed.

Key dates

02Disclosure timeline

November 15, 2023 CVE published
December 2, 2024 Record updated