CVE-2024-0569 MEDIUM

CVE-2024-0569: Totolink T8 Setting cstecgi.cgi getSysStatusCfg information disclosure

Vendor Totolink
Product T8
Weakness CWE-200 · Info exposure
Published January 16, 2024
Last update June 2, 2025

CVSS base score

5.3/10
Attack vector Network
Attack complexity Low
Privileges required Low
User interaction None
Confidentiality
Integrity

CVSS vector

CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N

What the vulnerability does

01Description

A vulnerability classified as problematic has been found in Totolink T8 4.1.5cu.833_20220905. This affects the function getSysStatusCfg of the file /cgi-bin/cstecgi.cgi of the component Setting Handler. The manipulation of the argument ssid/key leads to information disclosure. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. Upgrading to version 4.1.5cu.862_B20230228 is able to address this issue. It is recommended to upgrade the affected component. The identifier VDB-250785 was assigned to this vulnerability.

Key dates

02Disclosure timeline

January 16, 2024 CVE published
June 2, 2025 Record updated