CVE-2024-20458 HIGH

CVE-2024-20458: Cisco ATA 190 Series Analog Telephone Adapter Software Vulnerabilities

Vendor Cisco
Product Cisco Analog Telephone Adaptor (ATA) Software
Weakness CWE-78
Published October 16, 2024
Last update October 16, 2024

CVSS base score

8.2/10
Attack vector Network
Attack complexity Low
Privileges required None
User interaction None
Confidentiality None
Integrity High

CVSS vector

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:L

What the vulnerability does

01Description

A vulnerability in the web-based management interface of Cisco ATA 190 Series Analog Telephone Adapter firmware could allow an unauthenticated, remote attacker to view or delete the configuration or change the firmware on an affected device. This vulnerability is due to a lack of authentication on specific HTTP endpoints. An attacker could exploit this vulnerability by browsing to a specific URL. A successful exploit could allow the attacker to view or delete the configuration or change the firmware.

Key dates

02Disclosure timeline

October 16, 2024 CVE published
October 16, 2024 Record updated