CVE-2024-33698 CRITICAL

CVE-2024-33698

Vendor Siemens
Product Opcenter Quality
Weakness CWE-122
Published September 10, 2024
Last update October 14, 2025

CVSS base score

9.8/10
Attack vector Network
Attack complexity Low
Privileges required None
User interaction None
Confidentiality High
Integrity High

CVSS vector

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

What the vulnerability does

01Description

A vulnerability has been identified in Opcenter Quality (All versions < V2406), Opcenter RDnL (All versions < V2410), SIMATIC PCS neo V4.0 (All versions), SIMATIC PCS neo V4.1 (All versions < V4.1 Update 2), SIMATIC PCS neo V5.0 (All versions < V5.0 Update 1), SINEC NMS (All versions), SINEMA Remote Connect Client (All versions < V3.2 SP3), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions < V17 Update 8), Totally Integrated Automation Portal (TIA Portal) V18 (All versions < V18 Update 5), Totally Integrated Automation Portal (TIA Portal) V19 (All versions < V19 Update 3). Affected products contain a heap-based buffer overflow vulnerability in the integrated UMC component. This could allow an unauthenticated remote attacker to execute arbitrary code.

Key dates

02Disclosure timeline

September 10, 2024 CVE published
October 14, 2025 Record updated