CVE-2024-43652 CRITICAL

CVE-2024-43652: Authenticated command injection in the <redacted> action leads to full remote code execution as root on the charging station

Vendor Iocharger
Product Iocharger firmware for AC chargers
Weakness CWE-78
Published January 9, 2025
Last update March 11, 2025

CVSS base score

9.3/10
Attack vector Network
Attack complexity Low
Privileges required Low
User interaction None
Confidentiality
Integrity

CVSS vector

CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:L/SI:L/SA:H/S:P/AU:Y/R:U/V:D/RE:M

What the vulnerability does

01Description

Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701 Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services.

Key dates

02Disclosure timeline

January 9, 2025 CVE published
March 11, 2025 Record updated