CVE-2025-30042 CRITICAL

CVE-2025-30042: Session generation possible with certificate number only

Vendor Cgm
Product CGM CLININET
Weakness CWE-603
Published March 2, 2026
Last update March 2, 2026

CVSS base score

9.0/10
Attack vector Adjacent
Attack complexity Low
Privileges required None
User interaction None
Confidentiality
Integrity

CVSS vector

CVSS:4.0/AV:A/AC:L/AT:P/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H

What the vulnerability does

01Description

The CGM CLININET system provides smart card authentication; however, authentication is conducted locally on the client device, and, in reality, only the certificate number is used for access verification. As a result, possession of the certificate number alone is sufficient for authentication, regardless of the actual presence of the smart card or ownership of the private key.

Key dates

02Disclosure timeline

March 2, 2026 CVE published