CVE-2025-30645 HIGH

CVE-2025-30645: Junos OS: SRX Series: Transmission of specific control traffic sent out of a DS-Lite tunnel results in flowd crash

Vendor Juniper Networks
Product Junos OS
Weakness CWE-476
Published April 9, 2025
Last update April 24, 2025

CVSS base score

7.5/10
Attack vector Network
Attack complexity Low
Privileges required None
User interaction None
Confidentiality None
Integrity None

CVSS vector

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H

What the vulnerability does

01Description

A NULL Pointer Dereference vulnerability in the flow daemon (flowd) of Juniper Networks Junos OS on SRX Series allows an attacker causing specific, valid control traffic to be sent out of a Dual-Stack (DS) Lite tunnel to crash the flowd process, resulting in a Denial of Service (DoS).  Continuous triggering of specific control traffic will create a sustained Denial of Service (DoS) condition. On all SRX platforms, when specific, valid control traffic needs to be sent out of a DS-Lite tunnel, a segmentation fault occurs within the flowd process, resulting in a network outage until the flowd process restarts. This issue affects Junos OS on SRX Series: * All versions before 21.2R3-S9, * from 21.4 before 21.4R3-S9, * from 22.2 before 22.2R3-S5, * from 22.4 before 22.4R3-S6, * from 23.2 before 23.2R2-S3, * from 23.4 before 23.4R2.

Key dates

02Disclosure timeline

April 9, 2025 CVE published
April 24, 2025 Record updated