CVE-2025-34112 CRITICAL

CVE-2025-34112: Riverbed SteelCentral NetProfiler / NetExpress 10.8.7 RCE

Vendor Riverbed Technology
Product SteelCentral NetExpress
Weakness CWE-89 · SQLi
Published July 15, 2025
Last update April 7, 2026

CVSS base score

10.0/10
Attack vector Network
Attack complexity Low
Privileges required None
User interaction None
Confidentiality
Integrity

CVSS vector

CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H

What the vulnerability does

01Description

An authenticated multi-stage remote code execution vulnerability exists in Riverbed SteelCentral NetProfiler and NetExpress 10.8.7 virtual appliances. A SQL injection vulnerability in the '/api/common/1.0/login' endpoint can be exploited to create a new user account in the appliance database. This user can then trigger a command injection vulnerability in the '/index.php?page=licenses' endpoint to execute arbitrary commands. The attacker may escalate privileges to root by exploiting an insecure sudoers configuration that allows the 'mazu' user to execute arbitrary commands as root via SSH key extraction and command chaining. Successful exploitation allows full remote root access to the virtual appliance.

Key dates

02Disclosure timeline

July 15, 2025 CVE published
April 7, 2026 Record updated