CVE-2025-59105 HIGH

CVE-2025-59105: Unencrypted Flash Storage in dormakaba access manager

Vendor Dormakaba
Product Access Manager 92xx-k5
Weakness CWE-312 · Cleartext storage
Published January 26, 2026
Last update January 26, 2026

CVSS base score

7.0/10
Attack vector Physical
Attack complexity Low
Privileges required None
User interaction None
Confidentiality
Integrity

CVSS vector

CVSS:4.0/AV:P/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N

What the vulnerability does

01Description

With physical access to the device and enough time an attacker can desolder the flash memory, modify it and then reinstall it because of missing encryption. Thus, essential files, such as "/etc/passwd", as well as stored certificates, cryptographic keys, stored PINs and so on can be modified and read, in order to gain SSH root access on the Linux-based K7 model. On the Windows CE based K5 model, the password for the Access Manager can additionally be read in plain text from the stored SQLite database.

Key dates

02Disclosure timeline

January 26, 2026 CVE published