CVE-2026-25787 CRITICAL

CVE-2026-25787

Vendor Siemens
Product SIMATIC Drive Controller CPU 1504D TF
Weakness CWE-79 · XSS
Published May 12, 2026
Last update May 12, 2026

CVSS base score

9.1/10
Attack vector Network
Attack complexity Low
Privileges required High
User interaction None
Confidentiality High
Integrity High

CVSS vector

CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H

What the vulnerability does

01Description

Affected devices do not properly validate and sanitize Technology Object (TO) name rendered on the "Motion Control Diagnostics" page of the web interface. This could allow an authenticated attacker who is authorized to download a TIA project into the product, to inject malicious scripts into the page. If a benign user with appropriate rights accesses the "Motion Control Diagnostics" parameters page, the malicious code would be executed in the scope of their web session.

Key dates

02Disclosure timeline

May 12, 2026 CVE published
May 12, 2026 Record updated