CVE-2026-26985 HIGH

CVE-2026-26985: LORIS vulnerable to path traversal in electrophysiology_browser

Vendor Aces
Product Loris
Weakness CWE-22 · Path traversal
Published February 25, 2026
Last update February 25, 2026

CVSS base score

8.1/10
Attack vector Network
Attack complexity Low
Privileges required Low
User interaction None
Confidentiality High
Integrity High

CVSS vector

CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N

What the vulnerability does

01Description

LORIS (Longitudinal Online Research and Imaging System) is a self-hosted web application that provides data- and project-management for neuroimaging research. Starting in version 24.0.0 and prior to versions 26.0.5, 27.0.2, and 28.0.0, an authenticated user with the appropriate authorization can read configuration files on the server by exploiting a path traversal vulnerability. Some of these files contain hard-coded credentials. The vulnerability allows an attacker to read configuration files containing hard-coded credentials. The attacker could then authenticate to the database or other services if those credentials are reused. The attacker must be authenticated and have the required permissions. However, the vulnerability is easy to exploit and the application source code is public. This problem is fixed in LORIS v26.0.5 and v27.0.2 and above, and v28.0.0 and above. As a workaround, the electrophysiogy_browser in LORIS can be disabled by an administrator using the module manager.

Key dates

02Disclosure timeline

February 25, 2026 CVE published
February 25, 2026 Record updated